series type of actuation a, b port size 2 position 3 position one-touch fitting sy3 40 sy5 40 effective area mm 2 (cv factor) 4.68 (0.26) 12.6 (0.7) single double closed center exhaust center pressure center c4 (?) c6 (?) c8 (?) ?low power consumption: 0.55w (with light) (current value: 23ma, 24vdc) ?compact with high flow rate cv factor 1.7 to 3 times greater with same body width as previous series ?high reliability long life exceeding 50 million cycles ?main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise 44 rubber seal 5 port solenoid valve series sy3000/5000
how to order manifolds how to order valves how to order manifold assemblies example ss5y3-45gd-05u-c6 ..... 1 set (manifold part number) ? sy3140-5fu ....... 3 sets (single solenoid part number) ? sy3245-5fu ....... 1 set (double solenoid part number) ?valve stations are numbered from station 1 on the d side . ?indicate the valves to be mounted below the manifold part number, in order starting from station 1 as shown in the drawing. when a layout becomes complicated, please indicate it on a manifold specification sheet. ?since double and 3 position (dual body type) valves use two stations on a manifold base, be careful of the number of stations in manifold base part numbers. double solenoid sy3245-5fu (1 set) single solenoid sy3140-5fu (3 sets) manifold ss5y3-45gd-05u-c6 supply/exhaust block (u side mounting) 1 2 3 s ta tio n s d s id e u s id e 5 sy 3 1 fu 3 sy3000 5 sy5000 2 position single 5 sy 3 2 4 4 0 5fu double/3 position 2 2 position double 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center 5 24vdc nil r nil non-locking push type d e series type of actuation dual body type ( double/3 position) rated voltage pilot type manual override symbol applicable stations d u b 2 to 16 stations 2 to 10 stations 2 to 10 stations mounting position d side u side both sides m special specifications 3 sy3000 5 sy5000 series ? indicate special specifications separately on a manifold specification sheet. when a din rail is required that is longer than the standard type, specify the number of stations. (max. 20 stations) symbol mounting position u u side d d side connector mounting position valve stations 45g ss5y 3 05 u c4 d ?two stations are required for double and 3 position (dual body type). ?also includes the number of blanking plate assemblies. symbol port size ? one-touch fitting c4 ? one-touch fitting c6 ? one-touch fitting c8 mixed m symbol nil r s rs specifications sy5000 symbol port size ? one-touch fitting c4 ? one-touch fitting c6 mixed m sy3000 supply/exhaust block assembly mounting direction a, b port size supply/exhaust block assembly specifications options note single wiring specifications (up to 16 solenoids are possible) stations symbol 16 02 2 stations 16 stations 2 4 v d c + c o m + - s m c ? indicate mixed specifications separately on a manifold specification sheet. internal pilot specification external pilot specification internal pilot specification/built-in silencer external pilot specification/built-in silencer slotted locking type knob locking type internal pilot external pilot the " ? " symbol indicates mounting. put the " ? " symbol at the beginning of the part numbers for solenoid valves, etc., which are to be mounted. series sy3000/5000 45
manifold specifications solenoid valve specifications solenoid specifications response time rated coil voltage allowable voltage fluctuation power consumption surge voltage suppressor indicator light 24vdc 10% of rated voltage 0.55w diode led model manifold type p (sup), r (exh) system valve stations note1) port size a, b port piping specifications sy3000 sy5000 sy3000 sy5000 sy3000 sy5000 sy3000 sy5000 weight w (g) n: stations (d-sub connector) flat cable type 45g plug-in type common sup/exh base side c8 (? one-touch fitting) c10 (?0 one-touch fitting) c4 (? one-touch fitting)/c6 (? one-touch fitting) c4 (? one-touch fitting) c6 (? one-touch fitting)/c8 (? one-touch fitting) c6: p a/b 4.68 (0.26) a/b r 4.68 (0.26) c8: p a/b 12.6 (0.7) a/b r 12.6 (0.7) 2 to 16 stations 2 to 10 stations: w = 26n + 172 11 to 16 stations: w = 26n + 199 2 to 10 stations: w = 54n + 227 11 to 16 stations: w = 54n + 264 manual override pilot exhaust type mounting orientation impact/vibration resistance m/s 2 note) enclosure sy3000 sy5000 air 0.1 to 0.7 0.2 to 0.7 ?00kpa to 0.7 0.25 to 0.7 maximum 50 10 3 5 3 pilot valve individual exhaust type main valve/pilot valve common exhaust type lubrication not required unrestricted 150/30 dust proof 2 position single 2 position double 3 position operating pressure range 2 position single, double 3 position internal pilot external pilot non-locking push type slotted locking type, knob locking type 0.15 to 0.7 weights type of actuation with light/surge voltage suppressor response time ms 12 or less 2 position single 10 or less 2 position double 16 or less 3 position 19 or less 18 or less 32 or less type of actuation weight g 51 77 82 59 102 112.6 valve model single double closed center exhaust center pressure center single double closed center exhaust center pressure center 2 position 3 position 2 position 3 position sy3 45 sy3140 sy5 45 sy5140 sy3000 sy5000 location direction p / r ports a/b ports valve effective area mm 2 (cv factor) series fluid internal pilot operating pressure range mpa external pilot operating pressure range mpa ambient and fluid temperature c 2 position single 2 position double 3 position pilot pressure range max. operating frequency hz note) impact resistance: no malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states. (initial value) vibration resistance: no malfunction when tested with one sweep of 8.3 to 2000hz in the axial direction and at a right angle to the main valve and armature, in both energized and deenergized states. (initial value) response time ms with light/surge voltage suppressor type of actuation 2 position single 2 position double 3 position note 2) note 3) note) based on jisb8375-1981 dynamic performance test (with coil temperature of 20 c and at rated voltage). note 1) available with up to 16 solenoids. when a large number of valves will be operated simultaneously, use type b (supply/exhaust on both sides), applying pressure to the p ports on both sides and releasing exhaust from the r ports on both sides. note 2) the value is for manifold base mounting (5 stations). 2 position type with single action. note 3) the weight w is the value for the manifold only. to obtain the weight with solenoid valves, add the solenoid valve weights for the required number of stations. furthermore, when mounting supply/exhaust block assemblies on both sides of type b with a 2 to 10 station manifold, calculate the weight w using the formula for 11 to 16 stations. 46 5 port solenoid valve series sy3000/5000
sy3000: flat cable type/plug-in stations ss5y3-45gu- d- c4 c6 stations ss5y3-45gu- b- c4 c6 c4 c6 stations l1 l2 l3 l4 2 123 112.5 91.5 15.5 135.5 125 102 16.5 148 137.5 112.5 17.5 148 137.5 123 12.5 160.5 150 133.5 13.5 173 162.5 144 14.5 185.5 175 154.5 15.5 198 187.5 165 16.5 210.5 200 175.5 17.5 3456789 10 stations l1 l2 l3 l4 2 135.5 125 108 13.5 148 137.5 118.5 14.5 160.5 150 129 15.5 173 162.5 139.5 16.5 185.5 175 150 17.5 185.5 175 160.5 12.5 198 187.5 171 13.5 210.5 200 181.5 14.5 223 212.5 192 15.5 3456789 10 stations l1 l2 l3 l4 12 248 237.5 213 17.5 11 235.5 225 202.5 16.5 248 237.5 223.5 12 260.5 250 234 13 273 262.5 244.5 14 285.5 275 255 15 13 14 15 16 note) l1 to l4 dimensions of ss5y3-45gu- stations u- are the same as ss5y3? 45gu- stations d- . c4 c6 47 series sy3000/5000
stations ss5y3-45gd- u- c4 c6 stations ss5y3-45gd- b- c4 c6 stations l1 l2 l3 l4 2 123 112.5 91.5 15.5 135.5 125 102 16.5 148 137.5 112.5 17.5 148 137.5 123 12.5 160.5 150 133.5 13.5 173 162.5 144 14.5 185.5 175 154.5 15.5 198 187.5 165 16.5 210.5 200 175.5 17.5 345678910 stations l1 l2 l3 l4 2 135.5 125 108 13.5 148 137.5 118.5 14.5 160.5 150 129 15.5 173 162.5 139.5 16.5 185.5 175 150 17.5 185.5 175 160.5 12.5 198 187.5 171 13.5 210.5 200 181.5 14.5 223 212.5 192 15.5 345678910 stations l1 l2 l3 l4 12 248 237.5 213 17.5 11 235.5 225 202.5 16.5 248 237.5 223.5 12 260.5 250 234 13 273 262.5 244.5 14 285.5 275 255 15 13 14 15 16 c4 c6 c4 c6 note) l1 to l4 dimensions of ss5y3?5gd- stations d- are the same as ss5y3?5gd- stations u- . 48 5 port solenoid valve series sy3000/5000
sy5000: flat cable type/plug-in stations ss5y5-45gu- d- c4 c6 c8 stations ss5y5-45gu- b- c4 c6 c8 stations l1 l2 l3 l4 2 135.5 125 105 15 148 137.5 121 13.5 160.5 150 137 11.5 185.5 175 153 16 198 187.5 169 14.5 210.5 200 185 12.5 235.5 225 201 17 248 237.5 217 15.5 260.5 250 233 13.5 3456789 10 stations l1 l2 l3 l4 2 148 137.5 123 12.5 173 162.5 139 17 185.5 175 155 15 198 187.5 171 13.5 210.5 200 187 11.5 235.5 225 203 16 248 237.5 219 14.5 260.5 250 235 12.5 285.5 275 251 17 345678910 stations l1 l2 l3 l4 12 310.5 300 283 13.5 11 298 287.5 267 15.5 323 312.5 299 12 348 337.5 315 16.5 360.5 350 331 14.5 373 362.5 347 13 13 14 15 16 c4 c6 c8 c4 c6 c8 note) l1 to l4 dimensions of ss5y5-45gu- stations u- are the same as ss5y5-45gu- stations d- . 49 series sy3000/5000
stations ss5y5-45gd- u- c4 c6 c8 stations ss5y5-45gd- b- c4 c6 c8 stations l1 l2 l3 l4 2 135.5 125 105 15 148 137.5 121 13.5 160.5 150 137 11.5 185.5 175 153 16 198 187.5 169 14.5 210.5 200 185 12.5 235.5 225 201 17 248 237.5 217 15.5 260.5 250 233 13.5 345678910 stations l1 l2 l3 l4 2 148 137.5 123 12.5 173 162.5 139 17 185.5 175 155 15 198 187.5 171 13.5 210.5 200 187 11.5 235.5 225 203 16 248 237.5 219 14.5 260.5 250 235 12.5 285.5 275 251 17 345678910 stations l1 l2 l3 l4 12 310.5 300 283 13.5 11 298 287.5 267 15.5 323 312.5 299 12 348 337.5 315 16.5 360.5 350 331 14.5 373 362.5 347 13 13 14 15 16 c4 c6 c8 c4 c6 c8 note) l1 to l4 dimensions of ss5y5-45gd- stations d- are the same as ss5y5-45gd- stations u- . 50 5 port solenoid valve series sy3000/5000
sy3000: flat cable 20 pin type plug-in type, din rail manifold please copy this page for use without removing it. manifold valve specification sheet enter the symbols for the required specifications in the blanks below. enter the symbols for the required specifications in the blanks below. ?in the case of a single solenoid, enter an "x" in one station box. ? for double and 3 position, enter an "x" across two station boxes. (refer to the entry example below.) [when a, b port sizes are mixed, indicate the sizes in section (a) with c4 and c6.] note) connector blocks are not included in stations and layouts. 1 how to order manifolds 2 how to order valves 3 station table ss5y3-45g 2 stations single wiring specifications (up to 16 solenoids are possible.) note 16 stations 02 stations symbol 16 r s rs nil c4 c6 m ? one-touch fitting ? one-touch fitting mixed d b m 2 to 10 stations 2 to 16 stations u side d side both sides special specifications u ?also includes the number of blanking plate assemblies. ?since valves other than single solenoids are dual body types, they require two stations. u u side d d side connector mounting direction valve stations indicate mixed mounting in the station table below by entering c4 and c6 instead of "x's". a 140 standard dual body type 245 345 445 545 indicate in the station table below. type of valve actuation body option sy3 ??? ? 5fu nil d e non-locking push type slotted locking type knob locking type nil r pilot type valve stations or layout 2 position 1 quantity 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 3 position 3 port valve blanking plate assembly enter for special specs. supply/exhaust block assembly sup blocking disk single solenoid double solenoid valve stations or layout 2 position single solenoid double solenoid closed center exhaust center pressure center n.c. single n.c. double n.o. single n.o. double a a b c [entry example] refer to the entry example. 6 c6 54 c4 321 x x notes ?blanking plate assembly: sx3000-75-2a ?sup blocking disk: sx3000-77-1a ?exh blocking disk: sx3000-77-1a (2pcs./location) ?supply/exhaust block assembly (standard): sx3000-51-2a ?supply/exhaust block assembly (r): sx3000-51-6a ?supply/exhaust block assembly (s): sx3000-51-7a ?supply/exhaust block assembly (rs): sx3000-51-8a when the port sizes are mixed external pilot specification (enter only for external pilot) exh blocking disk (2pcs./location) a manual override company name contact person specification sheet no. purchase order no. equipment name quantity set(s) date required date / / options when a din rail is required that is longer than the standard type, specify the number of stations. (max. 20 stations) symbol specifications a, b port size symbol specifications supply/exhaust block assembly specifications standard/internal pilot specification external pilot specification internal pilot/built-in silencer external pilot/built-in silencer mounting position applicable stations symbol supply/exhaust block assembly mounting position symbol mounting position 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center internal pilot external pilot when using an external pilot valve, enter an "x" in the "external pilot specification" section of the station table below. order no. clerk (code no.) dept. code note) when there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for the supply/exhaust block assemblies together with the manifold model. for smc use only part no. quantity part no. quantity enter the ordered part numbers. indicate special specifications, in the station table below. make entries in order from to . 51
enter the symbols for the required specifications in the blanks below. ?in the case of a single solenoid, enter an "x" in one station box. ?for double and 3 position, enter an "x" across two station boxes. (refer to the entry example below.) [when a, b port sizes a re mixed, indicate the sizes in section (a) with c4 and c6.] enter the ordered part numbers. 2 how to order valves 3 station table ss5y5-45g 2 stations 16 stations 02 16 r s rs symbol nil c4 c6 m ? one-touch fitting c8 ? one-touch fitting mixed a, b port size d b m supply/exhaust block assembly mounting position symbol u ?also includes the number of blanking plate assemblies. ?since valves other than single solenoids are dual body types, they require two stations. u d valve stations a 140 245 345 445 545 indicate in the station table below. sy5 ??? ? 5fu d e nil r 1 quantity 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 a a b c 6 c6 54 c4 321 x x when the port sizes are mixed note) connector blocks are not included in stations and layouts. company name contact person specification sheet no. purchase order no. equipment name quantity set(s) date required date / / sy5000: flat cable 20 pin type plug-in type , din rail manifold please copy this page for use without removing it. manifold valve specification sheet enter the symbols for the required specifications in the blanks below. 1 how to order manifolds u side d side connector mounting direction symbol mounting position options when a din rail is required that is longer than the standard type, specify the number of stations. (max. 20 stations) ? one-touch fitting symbol specifications indicate mixed mounting in the station table below by entering c4, c6 and c8 instead of "x's". specifications supply/exhaust block assembly specifications standard/internal pilot specification external pilot specification internal pilot/built-in silencer external pilot/built-in silencer note stations symbol single wiring specifications (up to 16 solenoids are possible.) mounting position applicable station 2 to 10 stations 2 to 16 stations u side d side both sides special specifications in case of special specifications, indicate in the station table below. standard dual body type valve actuation/ body option 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center pilot type internal pilot external pilot when using an external pilot valve, enter an "x" in the "external pilot specification" section of the station table below. nil non-locking push type slotted locking type knob locking type a manual override valve stations or layout 2 position 3 position 3 port valve blanking plate assembly single solenoid double solenoid closed center exhaust center pressure center n.c. single n.c. double n.o. single n.o. double refer to the entry example. external pilot specification (enter only for external pilot) enter for special specs. supply/exhaust block assembly sup blocking disk valve stations or layout 2 position single solenoid double solenoid [entry example] exh blocking disk (2pcs./location) notes ?blanking plate assembly: sx5000-76-2a ?sup blocking disk: sx5000-77-1a ?exh blocking disk: sx5000-77-1a (2pcs./location) ?supply/exhaust block assembly (standard): sx5000-51-2a ?supply/exhaust block assembly (r): sx5000-51-6a ?supply/exhaust block assembly (s): sx5000-51-7a ?supply/exhaust block assembly (rs): sx5000-51-8a order no. clerk (code no.) dept. code note) when there are special specifications for the mounting position of supply/exhaust block assemblies, enter the part numbers and quantities for supply/exhaust block assemblies together with the manifold model. for smc use only part no. quantity part no. quantity make entries in order from to . 52